7135 Hardware RAID

From Wikistix

These are old IBM SCSI attached RAID controllers, identified as:

# lsdev -Cc disk
hdisk0 Available X0-05-01-0,0 7135 Disk Array Device
hdisk1 Available X0-05-01-0,1 7135 Disk Array Device

To check the RAID status, either use smitty raidiant, or:

# raidmgr -l dac0 -Q
 0 hdisk1  Raid 5 X0-05-01-0,1 17206 MB Status OPTIMAL
 1 hdisk0  Raid 5 X0-05-01-0,0 8594 MB Status OPTIMAL

Repeat the above for each DAC present on the system.

To find all installed disks:

# raidmgr -l dac0 -E
10 Channel 1 ID 0  Location LR-3  Non Existent Drive
20 Channel 2 ID 0  Location LR-6  Non Existent Drive
30 Channel 3 ID 0  Location LF-1  Optimal
40 Channel 4 ID 0  Location LF-6  Optimal
50 Channel 5 ID 0  Location LF-3  Optimal
11 Channel 1 ID 1  Location LR-4  Non Existent Drive
21 Channel 2 ID 1  Location LR-7  Non Existent Drive
31 Channel 3 ID 1  Location LF-2  Optimal
41 Channel 4 ID 1  Location LF-7  Optimal
51 Channel 5 ID 1  Location LF-4  Optimal
12 Channel 1 ID 2  Location LR-5  Non Existent Drive
22 Channel 2 ID 2  Location LR-8  Non Existent Drive
32 Channel 3 ID 2  Location LR-1  Non Existent Drive
42 Channel 4 ID 2  Location LF-8  Non Existent Drive
52 Channel 5 ID 2  Location LF-5  Non Existent Drive
13 Channel 1 ID 3  Location UF-8  Non Existent Drive
23 Channel 2 ID 3  Location UF-5  Non Existent Drive
33 Channel 3 ID 3  Location LR-2  Non Existent Drive
43 Channel 4 ID 3  Location UR-5  Non Existent Drive
53 Channel 5 ID 3  Location UR-8  Non Existent Drive
14 Channel 1 ID 4  Location UF-6  Optimal
24 Channel 2 ID 4  Location UF-3  Optimal
34 Channel 3 ID 4  Location UF-1  Non Existent Drive
44 Channel 4 ID 4  Location UR-3  Non Existent Drive
54 Channel 5 ID 4  Location UR-6  Non Existent Drive
15 Channel 1 ID 5  Location UF-7  Optimal
25 Channel 2 ID 5  Location UF-4  Optimal
35 Channel 3 ID 5  Location UF-2  Non Existent Drive
45 Channel 4 ID 5  Location UR-4  Non Existent Drive
55 Channel 5 ID 5  Location UR-7  Non Existent Drive